Skip to main navigation Skip to main content

Clin Mol Hepatol : Clinical and Molecular Hepatology

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR CONTRIBUTORS

Page Path

2
results for

"Gi Won Song"

Article category

Keywords

Publication year

"Gi Won Song"

Original Articles

Liver Transplantation

Resection plane-dependent error in computed tomography volumetry of the right hepatic lobe in living liver donors
Heon-Ju Kwon, Kyoung Won Kim, Bohyun Kim, So Yeon Kim, Chul Seung Lee, Jeongjin Lee, Gi Won Song, Sung Gyu Lee
Clin Mol Hepatol 2018;24(1):54-60.
Published online August 1, 2017
DOI: https://doi.org/10.3350/cmh.2017.0023
Background/Aims
Computed tomography (CT) hepatic volumetry is currently accepted as the most reliable method for preoperative estimation of graft weight in living donor liver transplantation (LDLT). However, several factors can cause inaccuracies in CT volumetry compared to real graft weight. The purpose of this study was to determine the frequency and degree of resection plane-dependent error in CT volumetry of the right hepatic lobe in LDLT.
Methods
Forty-six living liver donors underwent CT before donor surgery and on postoperative day 7. Prospective CT volumetry (VP) was measured via the assumptive hepatectomy plane. Retrospective liver volume (VR) was measured using the actual plane by comparing preoperative and postoperative CT. Compared with intraoperatively measured weight (W), errors in percentage (%) VP and VR were evaluated. Plane-dependent error in VP was defined as the absolute difference between VP and VR. % plane-dependent error was defined as follows: |VP–VR|/W∙100.
Results
Mean VP, VR, and W were 761.9 mL, 755.0 mL, and 696.9 g. Mean and % errors in VP were 73.3 mL and 10.7%. Mean error and % error in VR were 64.4 mL and 9.3%. Mean plane-dependent error in VP was 32.4 mL. Mean % plane-dependent error was 4.7%. Plane-dependent error in VP exceeded 10% of W in approximately 10% of the subjects in our study.
Conclusions
There was approximately 5% plane-dependent error in liver VP on CT volumetry. Plane-dependent error in VP exceeded 10% of W in approximately 10% of LDLT donors in our study. This error should be considered, especially when CT volumetry is performed by a less experienced operator who is not well acquainted with the donor hepatectomy plane.

Citations

Citations to this article as recorded by  Crossref logo
  • Radiomics Beyond Radiology: Literature Review on Prediction of Future Liver Remnant Volume and Function Before Hepatic Surgery
    Fabrizio Urraro, Giulia Pacella, Nicoletta Giordano, Salvatore Spiezia, Giovanni Balestrucci, Corrado Caiazzo, Claudio Russo, Salvatore Cappabianca, Gianluca Costa
    Journal of Clinical Medicine.2025; 14(15): 5326.     CrossRef
  • The Effect of Portal Vein Variants on the Margin of Error in Graft Volume Calculation in Living Donor Right Lobe Liver Transplantation
    Feyza Sönmez Topcu, Veysel Ersan, Emrah Şahin, Adem Tunçer, Hasret Ayyıldız Civan, Abuzer Dirican, Bülent Ünal
    Transplantation Proceedings.2025; 57(9): 1773.     CrossRef
  • Optimizing accuracy: a comparative analysis of preoperative liver volumetry in living donor liver transplantation from a surgeon’s perspective – a retrospective cohort study
    EunJin Choi, Seok-Hwan Kim
    International Journal of Surgery.2025; 111(11): 8149.     CrossRef
  • 3-D reconstruction in liver surgery: a systematic review
    Filippo Banchini, Patrizio Capelli, Anis Hasnaoui, Gerardo Palmieri, Andrea Romboli, Mario Giuffrida
    HPB.2024; 26(10): 1205.     CrossRef
  • Fully automated assessment of the future liver remnant in a blood-free setting via CT before major hepatectomy via deep learning
    Tingting Xie, Jingyu Zhou, Xiaodong Zhang, Yaofeng Zhang, Xiaoying Wang, Yongbin Li, Guanxun Cheng
    Insights into Imaging.2024;[Epub]     CrossRef
  • Accuracy of preoperative liver volumetry in living donor liver transplantation—A systematic review and meta-analysis
    Mika S. Buijk, Marcel Dijkshoorn, Roy S. Dwarkasing, Alicia C. Chorley, Robert C. Minnee, Markus U. Boehnert
    Journal of Liver Transplantation.2023; 10: 100150.     CrossRef
  • Prediction of Posthepatectomy Liver Failure with a Combination of Albumin-Bilirubin Score and Liver Resection Percentage
    Kazuhiro Takahashi, Masahiko Gosho, Jaejeong Kim, Osamu Shimomura, Yoshihiro Miyazaki, Kinji Furuya, Yoshimasa Akashi, Tsuyoshi Enomoto, Shinji Hashimoto, Tatsuya Oda
    Journal of the American College of Surgeons.2022; 234(2): 155.     CrossRef
  • CT and MR imaging evaluation of living liver donors
    Federica Vernuccio, Susan A. Whitney, Kadiyala Ravindra, Daniele Marin
    Abdominal Radiology.2021; 46(1): 17.     CrossRef
  • Estimation of the Right Posterior Section Volume in Live Liver Donors: Semiautomated CT Volumetry Using Portal Vein Segmentation
    So Yeong Jeong, Jeongjin Lee, Kyoung Won Kim, Jin Kyoo Jang, Heon-Ju Kwon, Gi Won Song, Sung Gyu Lee
    Academic Radiology.2020; 27(2): 210.     CrossRef
  • Reproducibility and reliability of computed tomography volumetry in estimation of the right‐lobe graft weight in adult‐to‐adult living donor liver transplantation: Cantlie’s line vs portal vein territorialization
    Heon‐Ju Kwon, Kyoung Won Kim, Jin Kyoo Jang, Jeongjin Lee, Gi‐Won Song, Sung‐Gyu Lee
    Journal of Hepato-Biliary-Pancreatic Sciences.2020; 27(8): 541.     CrossRef
  • Liver Graft Volume Estimation by Manual Volumetry and Software-Aided Interactive Volumetry: Which is Better?
    Birkan Bozkurt, Ertan Emek, Turkmen Arikan, Ozgur Ceyhan, Pinar Yazici, Tolga Sahin, Elmar Mammadov, Ayfer Serin, Nagihan Inan Gurcan, Yildiray Yuzer, Yaman Tokat
    Transplantation Proceedings.2019; 51(7): 2387.     CrossRef
  • Clinical implication of hepatic volumetry for living donor liver transplantation
    Woo Kyoung Jeong
    Clinical and Molecular Hepatology.2018; 24(1): 51.     CrossRef
  • MRI in donor candidates for living donor liver transplant: Technical and practical considerations
    Bohyun Kim, So Yeon Kim, Kyoung Won Kim, Hye Young Jang, Jong Keon Jang, Gi Won Song, Sung Gyu Lee
    Journal of Magnetic Resonance Imaging.2018; 48(6): 1453.     CrossRef
  • 13,569 View
  • 185 Download
  • 15 Web of Science
  • Crossref

Liver Transplantation

Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantation
Young Seo Cho, Kyoung Won Kim, Hye Young Jang, Bo Hyun Kim, Jeongjin Lee, Gi Won Song, Sung Gyu Lee, Dagvasumberel Munkhbaatar
Clin Mol Hepatol 2017;23(3):224-229.
Published online July 4, 2017
DOI: https://doi.org/10.3350/cmh.2016.0064
Background/Aims
Clinical validation is required to determine whether Doppler measurements are comparable before and after administering ultrasound contrast agent (USCA). The purpose of this study is to explore whether the use of USCA affects spectral Doppler analysis in recipients of liver transplantation (LT).
Methods
For this study, 36 patients were examined using Doppler ultrasonography (US) along with a contrast-enhanced US for surveillance of vascular complications after LT. The following spectral Doppler US parameters were measured before and after administration of USCA: peak systolic velocity, end-diastolic velocity, resistive index, and systolic acceleration time of the graft hepatic artery; peak flow velocity of the graft portal vein; and peak flow velocity and venous pulsatility index of the graft hepatic vein.
Results
The mean peak systolic and end-diastolic velocities of the hepatic artery and the peak flow velocity of the portal and hepatic veins were increased after intravenously administration of the USCA, ranging from 10% to 13%. However, the changes were not statistically significant (P=0.097, 0.103, 0.128, and 0.190, respectively). There were no significant differences in other measured parameters, including the resistive index (P=0.205) and systolic acceleration time (P=0.489) of the hepatic artery and venous pulsatility index (P=0.494) of the hepatic vein.
Conclusions
The measured velocities of graft hepatic vessels tended to increase after administration of USCA, but without statistical significance. The comparison of serial Doppler parameters with or without injection of USCA is valid during Doppler surveillance in recipients of LT.

Citations

Citations to this article as recorded by  Crossref logo
  • Effect of contrast-enhanced ultrasound (CEUS) on liver stiffness measurements obtained by transient and shear-wave elastography
    Stefano KAYALI, Andrea PASTA, Rinaldo PELLICANO, Sharmila FAGOONEE, Elisabetta GIULIANA, Chiara FACCHINI, Simona PILI, Silvia BUCCILLI, Sara LABANCA, Paolo BORRO
    Panminerva Medica.2022;[Epub]     CrossRef
  • 11,993 View
  • 128 Download
  • 1 Web of Science
  • Crossref