Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantation

Clinical and Molecular Hepatology 2017;23(3):224-229.
Published online: July 4, 2017

1Department of Radiology, Hanyang University Guri Hospital, Guri, Korea

2Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea

3Department of Radiology, Konyang University Hospital, Konyang University College of Medicine, Daejeon (current affiliation) Korea

4Department of Radiology, Ajou University Hospital, Suwon, Korea

5School of Computer Science & Engineering, Soongsil University, Seoul, Korea

6Division of Hepatobiliary and Liver Transplantation Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea

7Department of Radiology, School of Medicine, Mongolian National University of Medical Sciences, Ulaanbaatar, Mongolia

Corresponding author : Kyoung Won Kim Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea Tel: +82-2-3010-4385, Fax: +82-2-476-4719 E-mail: kimkw@amc.seoul.kr
• Received: September 26, 2016   • Revised: April 1, 2017   • Accepted: April 3, 2017

Copyright © 2017 by The Korean Association for the Study of the Liver

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 11,993 Views
  • 128 Download
  • 1 Web of Science
  • 1 Crossref
  • 2 Scopus
prev next

Citations

Citations to this article as recorded by  Crossref logo
  • Effect of contrast-enhanced ultrasound (CEUS) on liver stiffness measurements obtained by transient and shear-wave elastography
    Stefano KAYALI, Andrea PASTA, Rinaldo PELLICANO, Sharmila FAGOONEE, Elisabetta GIULIANA, Chiara FACCHINI, Simona PILI, Silvia BUCCILLI, Sara LABANCA, Paolo BORRO
    Panminerva Medica.2022;[Epub]     CrossRef

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantation
Clin Mol Hepatol. 2017;23(3):224-229.   Published online July 4, 2017
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantation
Clin Mol Hepatol. 2017;23(3):224-229.   Published online July 4, 2017
Close

Figure

  • 0
Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantation
Image
Figure 1. Box-and-whisker plot of the Doppler values of graft hepatic vasculature before and after administration of USCA. (A) The peak systolic velocity and end-diastolic velocity of the hepatic artery before and after administration of USCA. (B) The resistive indices and systolic acceleration time of the hepatic artery before and after administration of USCA. (C) The peak flow velocity of the portal vein before and after administration of USCA. (D) The peak flow velocity and venous pulsatility indices of the hepatic vein before and after administration of USCA. USCA, ultrasound contrast agent; PSV, peak systolic velocity; HA, hepatic artery; EDV, end-diastolic velocity; RI, resistive index; SAT, systolic acceleration time; PFV, peak flow velocity; PV, portal vein; HV, hepatic vein; VPI, venous pulatility index.
Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantation
Before USCA After USCA P-value
HA
 Peak systolic velocity (cm/s) 79.0 ± 45.2 89.0 ± 56.0 0.097
 End-diastolic velocity (cm/s) 23.0 ± 19.5 25.2 ± 22.1 0.103
 Resistive index 0.71 ± 0.12 0.72 ± 0.11 0.205
 Systolic acceleration time (ms) 65.3 ± 14.4 67.6 ± 19.7 0.489
PV
 Peak flow velocity (cm/s) 74.3 ± 35.4 82.0 ± 39.3 0.128
HV
 Peak flow velocity (cm/s) 47.0 ± 22.6 53.3 ± 27.8 0.190
 Venous pulsatility index 0.65 ± 0.41 0.68 ± 0.41 0.494
Table 1. Differences in mean Doppler values of graft hepatic vasculature before and after administration of USCA

Values are presented as mean ± SD unless otherwise indicated.